ookura_13-54_catalog_map


>> P.314

Mitutoyoreservestherighttochangeanyorallaspectsofanyproductspecification,includingprices,designsandservicecontent,withoutnotice.DigimaticIndicatorsABSOLUTEDigimaticIndicatorID-CSERIES543—BoreGageType•Dedicatedtoinsidediametermeasurementwithminimum-valueholdingandtolerancejudgmentfunctions*.UsetogetherwithaMitutoyoboregage(refertopages08-29to08-46fordetails).•Fivebuttons,statusicons,andclearbuttonindicationsalloweasyoperationandvariousfunctions.•Widedisplayandanalogbargrapharestandardonallmodels.•Uptothreesetsofmastervaluesandupper/lowertolerancevaluescanbestoredtosimplifythemastersetting.•Byusingtheparametersetupkit(optional)andthededicatedsoftware,thefunctionsandtheparameterscanbeconguredusingacomputer.*Tolerancejudgmentresultscannotbeoutput.Exampleofusewithaboregage(soldseparately)543-310B-10SPECIFICATIONSMetricISO/JISTypeCodeNo.Range(mm)Resolution(mm)Maximumpermissibleerror(MPE)*1(mm)PartialmeasuringrangeMPEPTotalmeasuringrangeMPEEHysteresisMPEHRepeatabilityMPERMaximumpermissiblelimit(MPL)Measuringforce(N)543-310B-1012.7Inch/Metric0.001/0.01(selectable)ISO/JISType0.0030.0030.0030.0021.5orlessBatterylife(normaluse)*2Mass(g)Approx.1year170CodeNo.RangeResolution543-311B-100.5in/12.7mm0.00005/0.0001/0.0005in,0.001/0.01mm(selectable)Maximumpermissibleerror(MPE)*1(mm)PartialmeasuringrangeMPEPTotalmeasuringrangeMPEEHysteresisMPEHRepeatabilityMPERMaximumpermissiblelimit(MPL)Measuringforce(N)Batterylife(normaluse)*2Mass(g)0.0030.0030.0030.0021.5orlessApprox.1year170Functions•MinimumvaluedetectionNote:Peakdetection1)Samplingrate:50readings/s2)Capturingspeed:50µm/s(max.)•Preset(3Presetvaluescanbestored)•Tolerancejudgment(3setsofupperandlowerlimitscanbestored)•Resolutionselection•Analogbarresolutionselection•Keylock•Displayhold(whennoexternaldeviceisconnected)•Datasaving/calling(whennoexternaldeviceisconnected)•Dataoutput•ExternalPCsettinginput•Displayrotation(330°)•Lowbatteryvoltagealarmdisplay•ErroralarmdisplayInch/MetricASME/ANSI/AGDtypeCodeNo.RangeResolutionMaximumpermissibleerror(MPE)*1(in)Overall*3HysteresisRepeatabilityMaximumpermissiblelimit(MPL)Measuringforce(N)Batterylife(normaluse)*2Mass(g)OptionalAccessoriesRefertopage07-13.•Parametersetupkit(optional)Refertopage07-13fordetails.543-312B-100.5in/12.7mm0.00005/0.0001/0.0005in,0.001/0.01mm(selectable)±0.000100.000100.000101.5orlessApprox.1year170TheABSOLUTEDigimaticBoreGage•Powersource:CR2032battery(1pc.),includedasstandard(foroperationalchecks)*1Thesevaluesapplytonormalmeasurementsat20°C.*2Appliesonlyifnotconnectedtoadataprocessor.Batterylifedependsonuseoftheindicator.Usetheabovevalueasaguideonly.*3OverallmagnicationandlinearityNote:Flat-backtypeonly.07-15ABSOLUTEDigimaticBoreGages,whichintegratethedisplaywithaboregagemeasuringunit,arealsoavailable.Refertopages08-47and08-48fordetails.


<< | < | > | >>